Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase built-in fuse metal armoured epoxy casting voltage transformer complying with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse (0.5A,50kA), net weight 95kg.
35kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Outdoor pole-mounted single-phase power transformer for 35kV systems. 1000/2000/3000VA capacity options. Epoxy resin cast, high insulation level. Compliant with IEC 60076 and GB 1094 standards. Provides control power for 35kV switchgear.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV with 2 Fuses
Outdoor single-phase epoxy resin casting voltage transformer with 2 primary fuses, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/√3/0.1/√3/0.1/3 kV, rated frequency 50/60Hz; accuracy rated output:30VA(0.2),60VA(0.5),100VA(1.0),100VA(6P); limiting thermal output of secondary winding 400VA; product weight:36kg; ambient operating temperature -5℃~+40℃.
Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 2 Fuses
Outdoor single-phase epoxy resin casting voltage transformer with residual winding and 2 primary fuses, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
Isolation-structure indoor voltage transformer with built-in fuse, compliant with GB/T20840.1/3 & IEC61869-1/3; insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse 0.5A 50kA, net weight 75kg.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.
Current Transformer Applied to CGIS Gas Insulated Switchgear
Indoor epoxy resin casting current transformer designed for CGIS gas insulated switchgear, with multiple accuracy class, rated burden and primary current options.
Current Transformer Applied to CGIS Gas Insulated Switchgear
Indoor epoxy resin casting current transformer designed for CGIS gas insulated switchgear, with multiple accuracy class, rated burden and primary current options.
Current Transformer Applied to CGIS Gas Insulated Switchgear
Indoor epoxy resin casting current transformer designed for CGIS gas insulated switchgear, with multiple accuracy class, rated burden and primary current options.
Current Transformer Applied to CGIS Gas Insulated Switchgear
Indoor epoxy resin casting current transformer designed for CGIS gas insulated switchgear, with multiple accuracy class, rated burden and primary current options.
35kV Indoor Epoxy Cast Current Transformer for Grid Metering
35kV indoor epoxy resin cast current transformer for power grid metering. Dual windings for 0.2S high-precision metering and protection. Rated output 10-15VA, wide primary current range. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge ensures long-term metering accuracy. Vacuum epoxy casting, compact pillar design, excellent insulation performance. Suitable for 35kV grid metering applications, customizable ratio.
35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV W2 outdoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting type current transformer, compliant with GB/T20840.1, GB/T20840.2 and IEC61869-1, IEC61869-2 standards, multiple primary current grades and accuracy combinations for selection.
Current Transformer for Inflatable Switchgear
Three-phase integrated current transformer for CGIS inflatable switchgear, multiple accuracy grades and wide primary current range available; secondary lead specifications and stacked product height support customized production.
Current Transformer for Inflatable Switchgear
Three-phase integrated current transformer for CGIS inflatable switchgear, multiple accuracy grades and wide primary current range available; secondary lead specifications and stacked product height support customized production.
LXK-Φ120TH Split-Core Zero Sequence Current Transformer for Earth Fault Protection
Waterproof zero sequence current transformer, model LXK-Φ120TH. Excellent waterproof performance for humid indoor environments. Rated up to 35kV, 50/60Hz. Split design with waterproof sealing ring, hot-line installation. TH tropicalized design, compliant with IEC 61869 standards. Used for three-phase cable ground fault protection.
Current Transformer for Inflatable Switchgear
Professional current transformer dedicated to CGIS inflatable switchgear with multiple accuracy grades and rich primary current specifications; secondary lead length and stacked mounting height support customized production.
Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor isolated structure metal armoured epoxy casting voltage transformer, meets GB/T20840.1/3 & IEC61869-1/3 standards; insulation level 40.5/95/200kV, shell full-grounding design, net weight 75kg.
Current Transformer for Inflatable Switchgear
Specialized current transformer for CGIS inflatable switchgear with multiple accuracy classes and abundant primary current specifications; secondary lead length and stacked product height support customized production.
Current Transformer for Inflatable Switchgear
Special current transformer for CGIS inflatable cabinets, multiple accuracy grades and primary current specifications available, customizable lead length and stackable product height.